Specifications
Electrical Measurements21
21-3
RMS Voltage
Selected Nominal
Voltage (Vnom)
Measurement Range
(CF 1.4 at full scale)
Resolution Accuracy
60 ... 125 Vrms 1.0 ... 250.0 Vrms 0.1 Vrms ± 0.5 % of Vnom
125 ... 250 Vrms 1.0 ... 500.0 Vrms 0.1 Vrms ± 0.5 % of Vnom
250 ... 500 Vrms 1.0 ... 999.9 Vrms 0.1 Vrms ± 0.5 % of Vnom
Peak Voltage
Selected Nominal
Voltage (Vnom)
Measurement Range
(CF 1.4 at full scale)
Resolution Accuracy
60 ... 125 Vrms 0 ... 350 V 1 V ± 5 % of Vnom
125 ... 250 Vrms 0 ... 700 V 1 V ± 5 % of Vnom
250 ... 500 Vrms 0 ... 1400 V 1 V ± 5 % of Vnom
Voltage Crest Factor
Condition Measurement Range Resolution Accuracy
Umeas Vnom 1.0 ... 2.8 0.1 ± 5 %
Harmonic and Interharmonic Voltages
Settings Range Additional Information
Harmonic selection (n): DC, 1 ... 50 Grouping: Harmonic Groups
according to IEC61000-4-7
Interharmonic selection: OFF, 1 ... 49 Grouping: Harmonic and
Interharmonic Su/jointfilesconvert/1235218/bgroups
according to IEC61000-4-7
Amplitude Reference total RMS / fund. RMS Used for Relative Amplitude
THD % total / % fundamental based on H1 ... H40