Set Up the Tester
13
AutoTest Configuration
Select Tools > AutoTest Configuration.
ffy42.bmp
Figure 8. AutoTest Configuration Screen
This screen allows you to enter up to ten key device
addresses (Targets) to test connectivity. You may enter an IP
address, URL, or DNS name. If no port is specified, AutoTest
will perform an ICMP Ping test to that address. If a port is
specified, AutoTest will perform a TCP Connectivity test
(SYN/ACK).
The Continuous Mode check box allows the test to run
continuously (checked) or one time (un-checked). When
you exit the AutoTest screen, the test is stopped.
PoE Configuration
Select Tools > PoE Configuration.
ffy34.bmp
Figure 9. PoE Configuration Screen
By default, PoE is disabled. This screen allows you to enable/
disable PoE detection, Enable TruePower
TM
, and set the Class
for detection. If you enable PoE and select Class 4 (25.5W),
you can also enable LLDP Negotiation so that PoE is only
reported if that criteria is met.
PoE TruePower
TM
is only available on the LR-AT 2000 model.
TruePower
TM
puts a load on the PoE device and gives an
accurate measurement on whether the device supports the
Class selected. See also, “Using the PoE Feature” on page
23.