Fluke T5-1000 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Auto Off
45 min
LO
+
+
Do not
overtighten
screw
OFF
2 AA
+
+
Specifications
Specifications subject to change without notice.
Calibration 1-year calibration cycle
Temperature
Operating:
Storage:
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating:
Storage:
2000 m (6562 ft)
10,000 m (32808 ft)
Relative
Humidity
0 % to 95 %, 5 °C to 30 °C
(41
°F to 86 °F); 0 % to 75 %,
30
°C to 40 °C
(86
°F to 104 °F); 0 % to 45 %,
40
°C to 50 °C
(104
°F to 122 °F)
Battery Type
and Life
AA (2); 360 hours continuous with
alkaline; 125 hours continuous with
zinc chloride
RF Field
Specification
0.5 % full scale + (specified accuracy)
at 3 V / m
Enclosure
Rating
IP 52 per IEC 60529, no vacuum
applied
Temperature
coefficient
0.1 x (specified accuracy) / °C for <18
°C or >28 °C (< 64.4 °F or > 82.4 °F)
Accuracy
± ( [ % of reading] + [number of least
significant digits] )
Accuracy is specified for 1 year after
calibration, at 18
°C to 28 °C
(64
°F to 82 °F) with relative humidity
to 90 %. AC conversions are ac-
coupled, average responding, and
calibrated to the rms value of a sine
wave input.
Function
T5-600
Range
(600 V
CAT III)
T5-1000
Range
(1000 V
CAT III)
Reso-
lution
Accuracy
600 V
rms
1000 V
rms
1 V ±(1.5 % + 2 digits)
45 Hz - 66 Hz
600 V 1000 V 1 V ±(1 % + 1 digit)
100.0 A 100.0 A
0.1 A
±(3 % + 3 digits)
45 Hz - 66 Hz
1000 1000 1 ±(1 % + 2 digits)
Replacement Parts
Test Lead Assembly.
Replace only with Fluke double-insulated
leads (
)
See "Accessories" for available
probes.
PN 648029
PN 2091779
rooD yrettaB
PN 8758161
wercS rooD yrettaB
Accessories
H
Use only specified replacement parts.
5 Belt Holster
TP1 Probe Set, Flat-Blade
AC285 SureGrip Alligator Clips
AC220 SureGrip Alligator Clips
Service Information Sheet, PN 686953
To contact Fluke, call:
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-67143114
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Visit Fluke's Web site at www.fluke.com.
Safety ......................... IEC 61010-1: Pollution Degree 2
Electromagnetic
Environment ................ IEC 61326-1: Portable
Warning
Disconnect test leads from power source
before opening battery door.
Před otevřením krytu baterie odpojte od
zdroje napájení měřicí přívody.
Przed otwarciem wnęki baterii należy
odłączyć przewody testowe od źródła
zasilania.
Перед тем как открыть крышку батарейного
отсека, отсоедините измерительные провода.
Pil kapağını açmadan önce test iletkenlerinin
güç kaynağıyla bağlantısını kesin.
Page view 1
1 2

Comments to this Manuals

No comments