Fluke 943-227-15 User Manual

Browse online or download User Manual for Unknown Fluke 943-227-15. Fluke 943-227-15 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Victoreen
®
Digital Preamplifier, Model 943-227-15,for use with
Model 943-27 Current Mode Beta Detector
Operator Manual
February 2008
Manual No. 943-227-15-1, Rev. 3
©2007, 2008 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies
Page view 0
1 2 3 4 5 6 ... 44 45

Summary of Contents

Page 1 - Victoreen

Victoreen® Digital Preamplifier, Model 943-227-15,for use with Model 943-27 Current Mode Beta Detector Operator Manual

Page 2 - 440.498.2564

943-227-15 Digital Preamplifier Operator Manual 1-6 1.4 Auxiliary Equipment Model Description None 1.5 Recommended Spare Parts Table 1-9. Rec

Page 3 - Table of Contents

General InformationSpare Parts/Receiving Inspection1 1-7 1.7 Storage Storage of Fluke Biomedical instruments must comply with Level B storage require

Page 4

(Blank Page)

Page 5 - General Information

Theory of OperationFunctional Description2 2-1 Section 2 Theory of Operation 2.1 Functional Description The Model 943-227-15 Digital Preamplifier i

Page 6 - 1.3 Specifications

943-227-15 Digital Preamplifier Operator Manual 2-2 INTEGRATING ELECTROMETERPGAALARM OUTPUTDAC EPROMANALOG SWITCHADCACIAHIGH VOLTAGE POWER SUPPLYRS

Page 7

Theory of OperationMain Circuit Boards2 2-3 Table 2-2. Electrometer Control Bit Assignments Bit Position 7 6 5 4 3 2 1 0 Description

Page 8

943-227-15 Digital Preamplifier Operator Manual 2-4 The following Test are provided on the 977-200-15M board: Table 2-4. 977-200-15M Test Points Te

Page 9

Theory of OperationCommunications2 2-5 Victoreen Communications Loop – 943-227-15VL Communication between the detector preamplifier and the UDR or 9

Page 10 - 1.6 Receiving Inspection

943-227-15 Digital Preamplifier Operator Manual 2-6 Table 2-8. Jumper Positions for Preamplifier Serial Interface Board 977-210-10M Jumper Normal

Page 11 - 1.7 Storage

OperationInstallation3 3-1 Section 3 Operation 3.1 Installation Installation consists of mounting the equipment, making the required electrical connec

Page 12 - (Blank Page)

Fluke Biomedical 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com

Page 13 - Theory of Operation

943-227-15 Digital Preamplifier Operator Manual 3-2 NOTE The electrometer circuitry in the preamplifier is highly sensitive to moisture and physical

Page 14 - Operator Manual

943-227-15 Digital Preamplifier Operator Manual 3-3

Page 15

OperationConfiguration3 3-4 3.3 Operation Operation of the 943-227-15 Digital Preamplifier is automatic and is controlled by the Model 942A-200C Digit

Page 16

943-227-15 Digital Preamplifier Operator Manual 3-5 For UDR systems, the address of the 942-200-80 Communications board in the UDR must be set 4040 a

Page 17

OperationConfiguration3 3-6 3.5 Set Point Error Codes Failure of the 943-227-17 preamplifier may result in the following error codes being displaye

Page 18

(Blank page)

Page 19 - Operation

Maintenance, Calibration and TroubleshootingMaintenance4 4-1 Section 4 Maintenance, Calibration and Troubleshooting 4.1 Maintenance The 943-227-15 Di

Page 20 - 3.2 Set-up

943-227-15 Digital Preamplifier Operator Manual 4-2 4.3 Troubleshooting WARNING Extreme care must be used when troubleshooting a system that has po

Page 21

AppendixConnector DesignationsA A-1 Appendix A Connector Designations A.1 CONNECTOR DESIGNATIONS, 943-227-15 and 943-227-15VL Table A-1. Field Ele

Page 22 - Alarms

943-227-15 Digital Preamplifier Operator Manual A-2 A.2 SWITCH AND JUMPER POSITIONS, 943-227-15 and 943-227-15VL Table A-2. Preamplifier Serial

Page 23 - Firmware Version

Table of Contents Section 1: General Information...

Page 24 - 3.6 Software Calculations

AppendixApplicable DrawingsB B-1 Appendix B Applicable Drawings B.1 Applicable Drawings 943-227-15 and 943-227-15VL Drawing No. Description943

Page 26 - Section 4

AppendixBill of MaterialsC C-1 Appendix C Bill of Materials C.1 Bill of Materials- 943-227-15 and 943-227-15VL Part Number Description 943-227-

Page 28 - Connector Designations

Appendix Cable Termination Instructions

Page 29 - 943-227-15 and 943-227-15VL

943-227-15 Digital Preamplifier Operator Manual D-2 Detector Field Cable Preparation, 943-227-15VL-M1, Conduit Hub: Prior to terminating the cable,

Page 30 - Applicable Drawings

Appendix Cable Termination Instructions

Page 31

943-227-15 Digital Preamplifier Operator Manual D-4

Page 32 - Bill of Materials

Appendix Cable Termination Instructions

Page 33

943-227-15 Digital Preamplifier Operator Manual D-6

Page 35

Appendix Cable Termination Instructions

Page 36 - HV CONNECTOR NOTES (HV)

943-227-15 Digital Preamplifier Operator Manual D-8

Page 37

AppendixModificationsE E-1 Appendix E Modification Sheets, Engineering Instructions E.1 Modification Sheets, Engineering Instructions P/N De

Page 38

(Blank page)

Page 39

(Blank page)

Page 40 - Appendix

Fluke Biomedical 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com

Page 41

General InformationGeneral Description1 1-1 Section 1 General Information 1.1 General Description The Victoreen® Model 943-227-15 Digital Preamplifier

Page 42 - Appendix E

943-227-15 Digital Preamplifier Operator Manual 1-2 Table 1-1. 943-227-15 Variations and Compatible Equipment Preamplifier Variations Application

Page 43

General InformationApplication1 1-3 Table 1-2. General Specifications for the 943-227-15 Digital Preamplifier Feature: Specification: Preamplifier P

Page 44

943-227-15 Digital Preamplifier Operator Manual 1-4 Table 1-3. Preamplifier Serial Interface Board 977-210-10M Switch Settings Switch Normal Op. Sw

Page 45

General InformationSpecifications1 1-5 Table 1-6. Field Electrical Connections, 943-227-15 and 943-227-15VL 943-227-15 943-27-15VL TB1- Descripti

Comments to this Manuals

No comments