Fluke 115 User Manual

Browse online or download User Manual for Thermometers Fluke 115. Fluke 115 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
®
September 2006 ©2006 Fluke Corporation. All rights reserved. 1
114, 115, 116, and 117
Digital Multimeters
Calibration Information
Introduction
XWWarning
To avoid electric shock or injury, do not perform the performance tests or
calibration adjustment procedures unless qualified to do so.
The information provided in this document is for the use of qualified personnel
only.
The 114, 115, 116, & 117 Calibration Information provides the information necessary to adjust and verify the
performance of the Fluke Models 114, 115, 115C, 116, 116C, 117, and 117C True RMS Multimeters (hereafter
known as the Meter). When specific models are noted in this manual, the “C” version is also included. For example,
when the listed model is 115, the instructions are applicable to the 115C as well.
The following information is included in this document:
Safety Information and International Electrical Symbols (page 2)
Specifications (page 3)
Testing the Fuse (page 5)
Replacing the Fuse and the Battery (page 6)
Cleaning (page 7)
Performance Tests (page 7)
Calibration Adjustment (page 12)
Replacement Parts and Accessories (page 17)
Complete Warranty (page 19)
See the 114, 115, 117 Users Manual or the 115C, 117C Users Manual or the 116 Users Manuals or the 116C Users
Manual for complete operating instructions.
Service Information
To contact Fluke, call one of the following telephone numbers:
USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's Web site at www.fluke.com
.
To register your product, visit register.fluke.com
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - 114, 115, 116, and 117

® September 2006 ©2006 Fluke Corporation. All rights reserved. 1 114, 115, 116, and 117 Digital Multimeters Calibration Information Introduction XW

Page 2 - Safety Information

114, 115, 116, and 117 Calibration Information 10 Table 3. DMM Performance Tests (cont) Display Reading Step Function Range Applied 114[1] 115[1] 11

Page 3 - General Specifications

Digital Multimeters Performance Tests 11 Table 3. DMM Performance Tests (cont) Display Reading Step Function Range Applied 114[1] 115[1] 116[

Page 4 - Accuracy Specifications

114, 115, 116, and 117 Calibration Information 12 STBY78250+/-4..SCOPEOUTTRIGAUXA SENSE AUXVNORMALV RTDTRUE RMS MULTIMETER117VoltAlertCenter Meter t

Page 5 - Basic Maintenance

Digital Multimeters Calibration Adjustment 13 2. Press g once to see the calibration counter. 3. Press g again to start the password entry.

Page 6 - XWWarning

114, 115, 116, and 117 Calibration Information 14 Meter Buttons Used in the Calibration Steps When performing the Calibration Adjustment Procedure, th

Page 7

Digital Multimeters Calibration Adjustment 15 Notes Set the calibrator to Standby prior to changing the function switch position and after com

Page 8

114, 115, 116, and 117 Calibration Information 16 Table 4. Calibration Adjustment Steps (cont) Calibration Steps Rotary Switch Position 114 115[1] 116

Page 9

Digital Multimeters Replacement Parts 17 Replacement Parts Table 5 lists the Meter’s replacable parts identified in Figure 6. 6121023201721975

Page 10 - Calibration Information

114, 115, 116, and 117 Calibration Information 18 Table 5. Replacable Parts List Item Description Part Number Qty. 1 LCD,FLUKE-11X,3.2V,TN,4-DIGIT,1/

Page 11 - Performance Tests

Digital Multimeters Warranty 19 Table 5. Replaceable Parts List Item Description Part Number Qty. 19 BATTERY,PRIMARY,MNO2-ZN,9V,505MAH,6LR61,

Page 12 - Calibration Adjustment

114, 115, 116, and 117 Calibration Information 2 Safety Information "Warning" and "Caution" Statements A “XW Warning" ident

Page 13 - XW Warning

114, 115, 116, and 117 Calibration Information 20

Page 14

Digital Multimeters International Electrical Symbols 3 International Electrical Symbols Table 1 lists the international symbols that appear in

Page 15

114, 115, 116, and 117 Calibration Information 4 Accuracy Specifications Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model[1] DC

Page 16

Digital Multimeters Basic Maintenance 5 Accuracy Specifications (cont) Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model[

Page 17 - Replacement Parts

114, 115, 116, and 117 Calibration Information 6 HOLD MIN MA X RANGE10 AFUSEDCOMVALo / HOFFHzHzAUTO-VLoZVoltAlertAAVVmVVoltA le rtTRUE RMS MULTIMETE

Page 18

Digital Multimeters Performance Tests 7 2. Remove the Meter from its holster. 3. Remove two screws from the case bottom. 4. Separate the ca

Page 19 - Warranty

114, 115, 116, and 117 Calibration Information 8 Table 2. Required Equipment (cont) Recommended Equipment Measurement Function Accuracy 5500A Multi-

Page 20

Digital Multimeters Performance Tests 9 2. Warm up the calibrator as required by its specifications. 3. Allow the temperature of the UUT to