3125
Detachable Hot Plate
Users’ Manual
Rev. 622101
Hart Scientific
http://www.rongqe.cn/
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Users’ Manual

3125Detachable Hot PlateUsers’ ManualRev. 622101Hart Scientifichttp://www.rongqe.cn/

Page 3 - Table of Contents

2 IntroductionHart Scientific’s Model 3125 Detachable Hot Plate is controlled by Hart Scien-tific’s 2200 controller and uses a precision platinum RTD

Page 5 - 1 Before You Start

3 Specifications and EnvironmentalConditions3.1 SpecificationsTemperature Range 35°C to 400°C (95°F to 752°F)Display Accuracy ±0.5°C to 200°C±1.0°C to

Page 6 - 1.2 Safety Information

•ambient relative humidity: maximum 80% for temperature <31°C, de-creasing linearly to 50% at 40°C•pressure: 75kPa-106kPa•mains voltage within ±10%

Page 7 - Safety Information

4 Troubleshooting4.1 Troubleshooting Problems, Possible Causes,and SolutionsIn the event that the instrument appears to function abnormally, this sect

Page 8 - Cautions

Problem Possible Causes and SolutionsThe display shows anyof the following:err 1,err 2,err 3,err4,Err 5,Err 6,orErr 7Controller problem. The error mes

Page 9 - Authorized Service Centers

Limited Warranty & Limitation of LiabilityEach product from Fluke's Hart Scientific Division ("Hart") is warranted to be free from

Page 10

Table of Contents1 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Symbols Used . . . . . . .

Page 12

1 Before You Start1.1 Symbols UsedTable 1 lists the International Electrical Symbols. Some or all of these symbolsmay be used on the instrument or in

Page 13 - Conditions

Symbol DescriptionCanadian Standards AssociationOVERVOLTAGE (Installation) CATEGORY II, Pollution Degree 2 per IEC1010-1 re-fers to the level of Impul

Page 14

cautions. Before working inside the equipment, turn the power off anddisconnect the power cord.•Always replace the fuse with one of the same rating, v

Page 15 - 4 Troubleshooting

1.2.2Cautions•DO NOT plug the unit into 230V if the heater switches and fuse holderread 115V. This action will cause the fuses to blow and may damage

Page 16 - 4.2 Comments

NETHERLANDSPhone: +31-402-675300Telefax: +31-402-675321E-mail: [email protected] Int'l CorporationService Center - InstrimpexRoom 2301 Sc