®Models 175, 177, 179True RMS MultimetersUsers ManualMay 2003 (English)© 2003 Fluke Corporation. All rights reserved. Printed in USA.
Models 175, 177 & 179Users Manual6Making Basic MeasurementsThe figures on the following pages show how to make basicmeasurements.When connecting t
Making Basic Measurements7Testing for ContinuityRANGEHOLDMIN MAXRANGEHOLDMIN MAXAIK06F.EPSMeasuring Temperature (Model 179 Only)RANGEHOLDMIN MAX80BK1
Models 175, 177 & 179Users Manual8Measuring AC or DC CurrentWarningTo avoid personal injury or damage to the Meter:• Never attempt to make an in-
Using the Bar Graph9Measuring FrequencyWarningTo avoid electrical shock, disregard the bar graph forfrequencies > 1 kHz. If the frequency of the me
Models 175, 177 & 179Users Manual10CleaningWipe the case with a damp cloth and mild detergent. Do not useabrasives or solvents. Dirt or moisture i
Specifications11SpecificationsAccuracy is specified for 1 yr after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at
Models 175, 177 & 179Users Manual12Accuracy ± ( [ % of Reading ] + [ Counts ] )Function Range 1Resolution Model 175 Model 177 Model 179AC Volts 2
Specifications13Accuracy ± ( [ % of Reading ] + [ Counts ] )Function Range 1Resolution Model 175 Model 177 Model 179DC Amps460.00 mA400.0 mA6.000 A10
Models 175, 177 & 179Users Manual14Function Overload Protection 1Input Impedance(Nominal)Common Mode Rejection Ratio(1 kΩ Unbalanced) Normal Mode
Lifetime Limited WarrantyEach Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in material and workmanship for its lifetime. As used
iTable of ContentsTitle PageContacting Fluke ...
iiWarning. Read before using the Meter:To avoid possible electrical shock or personal injury, follow these guidelines:⇒ Use the Meter only as specifi
1Models 175, 177 & 179True RMS MultimetersThe Fluke Model 175, Model 177, and Model 179 are battery-powered, true-RMS multimeters (hereafter "
Models 175, 177 & 179Users Manual2Battery Saver ("Sleep Mode")The Meter enters the "Sleep mode" and blanks the display if ther
Display3Display.8775643211314159111210AIK02F.EPSNo. Symbol Meaning1 sContinuity test.2 Diode test.3 KNegative readings.4 YUnsafe voltage. Voltage ≥ 30
Models 175, 177 & 179Users Manual4MIN MAX AVG Recording ModeThe MIN MAX AVG recording mode captures the minimum andmaximum input values, and calcu
Manual Ranging and Autoranging5Manual Ranging and AutorangingThe Meter has both Manual range and Autorange modes.⇒ In the Autorange mode, the Meter s