November 2010 © 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of
1551A/1552A Ex Users Manual 2 • 300 hour battery life • Percent battery life and low-battery indicator • NVLAP accredited calibration (NIST tracea
Stik Thermometer Safety Information 3 • Check for proper operation of the Product before taking it into a hazardous area. Should the Product not
1551A/1552A Ex Users Manual 4 Symbols International symbols used on the Product and in this manual are explained in Table 1. Table 1. Symbols Symbol M
Stik Thermometer Operation 5 Operation Immersion Depth and Usage WCaution To prevent possible damage to the Product or to equipment under test, do
1551A/1552A Ex Users Manual 6 The minimum immersion depth for the Probe is 3.5 inches in a stirred fluid heat source. It is recommended that you make
Stik Thermometer Operation 7 Display and Controls The Display and Controls are explained below and in the Setup and Configuration section. See Fi
1551A/1552A Ex Users Manual 8 Primary Display Push Ato toggle the numeric display between the current reading, minimum, maximum, and 1-minute trend va
Stik Thermometer Operation 9 Auto-Off Selection The Auto-off parameters control when the Product automatically turns off after inactivity on the k
1551A/1552A Ex Users Manual 10 Display Resolution Display resolution is the number of digits to the right of the decimal point. The settings are 0.1,
Stik Thermometer Maintenance 11 Logging Interval Push C to enter the data edit mode. ENTER is ignored if presently logging data. K Change the lo
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use an
1551A/1552A Ex Users Manual 12 To change the batteries, see Figure 4: 1. Use a flat-blade screwdriver to remove the battery door screw. 2. Remove t
Stik Thermometer SCPI Commands 13 Battery Life Battery life is approximately 300 hours (12.5 days) of continuous operation with the backlight off.
1551A/1552A Ex Users Manual 14 Battery Life ... Approximately 300 hours w
i Table of Contents Title Page Introduction...
1551A Ex/1552A Ex Users Manual ii
iii List of Tables Table Title Page 1. Symbols...
1551A Ex/1552A Ex Users Manual iv
v List of Figures Figure Title Page 1. Probe Measurements ...
1551A Ex/1552A Ex Users Manual vi
1 Introduction The Stik Thermometer (the Product) is a precision digital thermometer that can be used as an alternative to mercury liquid-in-glass (L